Telegraf: Input - Windows Performance Counters: Unterschied zwischen den Versionen
Aus Wiki-WebPerfect
Admin (Diskussion | Beiträge) K |
Admin (Diskussion | Beiträge) K |
||
Zeile 7: | Zeile 7: | ||
== Cause == | == Cause == | ||
''This is because of an syntax error. You will setting two different tags on the same win_perf_stanza (<nowiki>[[inputs.win_perf_counters]]</nowiki>).'' <br> | ''This is because of an syntax error. You will setting two different tags on the same win_perf_stanza (<nowiki>[[inputs.win_perf_counters]]</nowiki>).'' <br> | ||
− | ''In the Telegraf input plugin "win_perf_counters" you cannot set the tags under the [[inputs.win_perf_counters. | + | ''In the Telegraf input plugin "win_perf_counters" you cannot set the tags under the <nowiki>[[inputs.win_perf_counters.object]]</nowiki> stanza (object stanza).'' <br> |
− | ''You have to set the tags under the [[inputs.win_perf_counters]] stanza and cannot define it twice like the following image:'' <br> | + | ''You have to set the tags under the <nowiki>[[inputs.win_perf_counters]]</nowiki> stanza and cannot define it twice like the following image:'' <br> |
[[Datei:01-telegraf win perf counters wrong tag.png]] | [[Datei:01-telegraf win perf counters wrong tag.png]] | ||
== Solution == | == Solution == | ||
− | *Create a new [[inputs.win_perf_counters]] stanza foreach input that should have different tags. Like this: <br> | + | *Create a new <nowiki>[[inputs.win_perf_counters]]</nowiki> stanza foreach input that should have different tags. Like this: <br> |
Version vom 8. Februar 2022, 08:47 Uhr
Error
E! [telegraf] Error running agent: Error loading config file <PATH_TO_YOUR_CONFIG>.conf: Error parsing data: line x: table `inputs.win_perf_counters.tags' is in conflict with table in line x
Cause
This is because of an syntax error. You will setting two different tags on the same win_perf_stanza ([[inputs.win_perf_counters]]).
In the Telegraf input plugin "win_perf_counters" you cannot set the tags under the [[inputs.win_perf_counters.object]] stanza (object stanza).
You have to set the tags under the [[inputs.win_perf_counters]] stanza and cannot define it twice like the following image:
Solution
- Create a new [[inputs.win_perf_counters]] stanza foreach input that should have different tags. Like this:
inputs.win_perf_counters.object ObjectName = "Hyper-V Hypervisor Virtual Processor" Instances = ["*"] Counters = [ "Hypercalls/sec", ] Measurement = "hyperv_vm_hypercalls_demo"
[inputs.win_perf_counters.tags]
TestTag = "testvalue1"
inputs.win_perf_counters.object ObjectName = "Hyper-V Hypervisor Virtual Processor" Instances = ["*"] Counters = [ "Hypercalls/sec", ] Measurement = "hyperv_vm_hypercalls_demo"
[inputs.win_perf_counters.tags]
TestTag = "testvalue2"